Skip to content
BackBoat AlmanacSign inAdd for free

Cable size and voltage drop

The cable cross-section a DC circuit needs for its length and current. The calculations run in your browser.

🔌 Cable size and voltage drop

How it is worked out

A DC circuit runs from the battery to the load and back, so the copper is twice the one-way length. Cross-section = 2 × length × current × 0.0175 (resistivity of copper in Ω·mm²/m) ÷ allowed voltage drop. Boat standards such as ISO 10133 and ABYC E-11 use 3% for loads where a low voltage is a safety or reliability problem and 10% for the rest.

The cable must also carry the current without overheating. On short runs with a high current (a windlass or an inverter close to the battery) this, not the voltage drop, sets the size. The calculator checks both, using typical ratings for 105 °C marine cable and about 15% less in an engine room, and gives the larger size. It never suggests less than 1 mm² (16 AWG).

Marine wiring in short

Not for navigation. These tools give estimates from simple models; they support good seamanship and do not replace it. Check every result against official charts, tide tables, nautical publications, your instruments and the conditions you see. The skipper is responsible for the boat and the people on board.

More tools

24 calculators and planners

All calculators and planners

Know these waters?

Free and quick. What you add helps the next crew decide.

Boat Almanac is free for every sailor and grows with what sailors add.